Project · Indoor tennis · Bassillac

LED lighting for 2 indoor tennis courts in Bassillac: photometric study and on-site measurements

For this new-build project in Dordogne, STADÉLUM supported the selection of the lighting solution, floodlight layout, photometric study and comparison with on-site measurements taken after installation.

2 indoor courts COURTLINE 8 floodlights per court 7 m mounting height On-site measurements available
LED lighting for indoor tennis courts in Bassillac with STADÉLUM COURTLINE floodlights
LED installation completed on two indoor tennis courts, with a comparison between the photometric study and on-site measurements.
2 indoor courts
8 COURTLINE per court
7 m mounting height
2,240 W installed per court
619 lux measured average

Project context

Indoor tennis lighting designed before installation

The challenge was not simply to supply luminaires. The project had to verify the amount of useful light on the courts, uniformity, correct beam distribution and players' visual comfort within an indoor structure.

  • Analysis of the structure, available height and mounting areas.
  • Selection of suitable optics to distribute light across the playing area.
  • Targeting a level of uniformity suited to indoor tennis use.

STADÉLUM method

A technical approach: study, layout and verification

STADÉLUM highlights this project because it demonstrates the value of carrying out a photometric study beforehand and verifying the results on site when conditions allow.

Site analysis

Height, structure, setback, mounting constraints and areas to be lit are taken into account before selecting the product.

Layout

The floodlights are positioned to cover the courts without unnecessarily concentrating the light.

Optics selection

The luminaire optics are used to control light distribution, rather than focusing solely on power.

On-site measurements

The available measurements make it possible to compare the achieved performance with the initial targets.

Photometric study

Simulation, illuminance plan and light distribution assessment

Photometric study of an indoor tennis court in Bassillac with isolux curves and measurement points
Photometric plan: visualisation of illuminance levels and light distribution across the court.
3D DIALux photometric simulation of an indoor tennis court in Bassillac
3D simulation: assessment of the floodlight layout within the indoor structure.

Measured results

On-site values clearly distinguished from the study

The data below corresponds to the information provided for the Bassillac project. It should not be generalised to other buildings or mounting heights without a dedicated study.

Measured average illuminance 619 lux

Result measured after installation.

Actual U0 uniformity 0.70

Measured minimum-to-average ratio.

Installed power 2.24 kW

Per court, with 8 COURTLINE floodlights.

An average level of 500 lux and U0 0.70 uniformity are used here as technical reference values for indoor tennis. Any statement of official compliance must be verified against the project specifications and applicable documents.

Product used

COURTLINE: a linear floodlight designed for the constraints of indoor courts

For this project, the COURTLINE solution was selected to optimise the layout, light distribution and installed power.

  • 8 COURTLINE floodlights per court.
  • Installed at approximately 7 m.
  • Controlled installed power: 2,240 W per court.
  • Visual comfort and glare limitation taken into account.

Technical summary

Data Provided value
SportIndoor tennis
LocationBassillac, Dordogne
Number of courts2
ProductCOURTLINE
Layout8 floodlights per court
Height7 m
Installed power2,240 W per court
On-site measurement619 lux average, U0 0.70

Technical FAQ

Frequently asked questions about indoor tennis court lighting

Why carry out a photometric study before lighting an indoor tennis court?

Because the result depends on the height, layout, optics, reflections and structure. The study makes it possible to anticipate lux levels, uniformity and areas with lower light levels.

Is installed power enough to assess the quality of sports lighting?

No. High power does not guarantee well-distributed light. Optics selection, floodlight aiming and uniformity are decisive factors.

Are the stated 619 lux a simulation?

No. For this project, the average 619 lux and U0 0.703 are presented as results measured on site.

Indoor tennis project

A lighting project should be studied before it is priced

STADÉLUM can analyse your site, check the available height, propose a layout, study the optics, estimate lux levels, uniformity, visual comfort and the required installed power.

Request a technical study