High-power lighting for large outdoor areas
Stadium LED floodlights from 600 to 1,800 W
Football, rugby, stadiums and large sports complexes
This category includes floodlights designed for installations where projection distance, mast height and the area to be illuminated require high lumen output. The solution must be defined on the basis of the photometric study, optics, mast-head configuration, wind loads and total installed power.
Project design
High power cannot compensate for poor positioning
On a large sports ground, the objective is not simply to provide a large amount of light. The lumen output must be distributed over a long distance while maintaining consistent uniformity, minimising poorly lit areas and avoiding aiming angles that may cause discomfort to players or nearby residents.
The choice between the 600, 1,200, 1,500 and 1,800 W versions must therefore be linked to mast height, setback distance, the number of masts, the optics and the operating scenarios.
Applications to assess
Floodlights designed for large outdoor sports areas
Football
Training pitch, main pitch or stadium: mast height and positioning must be consistent with the project's lighting objectives.
Rugby
Long playing areas, high ball trajectories and the need for stable light distribution throughout the playing volume.
Stadiums and sports complexes
Multiple pitches, stands or activity areas may require different lighting scenarios and aiming directions.
Large outdoor areas
Any other large sports area must be assessed according to its geometry, surroundings, intended uses and project specifications.
Technical criteria
Six parameters shape stadium lighting design
Mast height
It determines throw distance, aiming angles and the number of lighting points.
Optics
The beam shape must match the projection distance and the actual target area.
Glare
Aiming directions and accessories must protect the visual comfort of players and nearby residents.
Wind and Scx
The Scx of each luminaire must be combined with that of the crossarms and mast-head equipment.
Mast-head equipment
Modular crossarm, platform or other support depending on the number and weight of the luminaires.
Installed power
The number of floodlights and their power ratings should be optimised within the same calculation.
Main product in this category
ARENA STADIUM: four power levels to build the right configuration
High-power outdoor LED floodlight
ARENA STADIUM
ARENA STADIUM is available in four power ratings to adapt the lumen output to projection distance and positioning. The range features an integrated DALI driver, C5 corrosion resistance and an optional anti-glare visor.
| Reference | Power | Stated lumen output | Optic | Weight | Scx at 15° / 60° |
|---|---|---|---|---|---|
| STAAREN600W | 600 W | 92,336 lm | 130° × 56° | 15.3 kg | 0.07 / 0.14 m² |
| STAAREN1K2W | 1,200 W | 190,957 lm | 110° × 56° | 27.6 kg | 0.11 / 0.28 m² |
| STAAREN1K5W | 1,500 W | 221,230 lm | 110° × 56° | 29.6 kg | 0.11 / 0.22 m² |
| STAAREN1K8W | 1,800 W | 263,000 lm | 110° × 56° | 37.9 kg | 0.15 / 0.42 m² |
Important: a higher power rating does not automatically result in a better project. The version must be selected together with the optic, mast position, aiming angles, number of luminaires and the mechanical capacity of the complete assembly.
Related supports
The floodlight, mast and crossarm must be sized as a complete system
SKY / CLIMB masts
Tapered round or polygonal solutions for sports grounds requiring significant mounting heights and several luminaires at mast head.
View SKY / CLIMB
STADIUM masts
12- or 16-sided polygonal masts to be selected according to height, mast-head configuration, wind conditions and permissible loads.
View STADIUM masts
Modular crossarms
They allow several heavy floodlights to be arranged on the mast head and must be combined with clamps suitable for the relevant mast family.
View MODULAR crossarmsSTADÉLUM method
Define the layout before selecting power ratings
The ARENA STADIUM configuration is developed from the constraints of the site and the project's lighting objectives, then checked against the mechanical capacities of the masts and mast-head equipment.
-
01
Analyse the site
Dimensions, use, environment, neighbouring areas and zones to be protected.
-
02
Position the masts
Quantity, setback, height and realistic installation possibilities.
-
03
Simulate the optics
Power ratings, aiming, uniformity, glare and spill light.
-
04
Check the mast head
Weight, Scx, crossarms, wind loads, cabling and total installed power.
Frequently asked questions
Preparing a stadium lighting project
How do you choose between 600 W and 1,800 W?
Projection distance, mast height, optics, the number of masts, the required illuminance level and uniformity must all be assessed. The highest power rating is not automatically the best solution.
Can an existing floodlight be replaced with an ARENA of the same wattage?
The same wattage does not guarantee equivalent photometric performance. The optic, lumen output, positioning, weight, Scx, mounting system and total installation power must be compared.
Why are weight and Scx so important?
They contribute to the sizing of the mast head. The verification must include each floodlight, the crossarm, clamps, cables and all other accessories exposed to wind.
Does ARENA STADIUM include lighting control?
The technical data sheet specifies an integrated DALI driver. Operating scenarios and the control system must be defined according to the electrical installation and the site's requirements.
Assess the site before selecting and pricing the floodlights
Which ARENA STADIUM configuration is right for your project?
Send us the site plan, the existing or proposed mast positions, mast heights, the required usage level and photographs of the site. STADÉLUM will assess the optics, light distribution, power requirements and loads.
Request a preliminary study
Français
Español
Deutsch
English