ARENA STADIUM – LED stadium floodlight | STADÉLUM
  • ARENA STADIUM – LED stadium floodlight | STADÉLUM
  • ARENA STADIUM – LED stadium floodlight | STADÉLUM
  • ARENA STADIUM – LED stadium floodlight | STADÉLUM
  • ARENA STADIUM – LED stadium floodlight | STADÉLUM
  • ARENA STADIUM – LED stadium floodlight | STADÉLUM
  • ARENA STADIUM – LED stadium floodlight | STADÉLUM

ARENA STADIUM: high-power LED floodlight for outdoor sports fields

€971.74
Tax excluded

ARENA STADIUM is a high-power LED floodlight designed for illuminating football pitches, rugby fields, stadiums, and large outdoor multi-sport complexes. Available in 600 W, 1,200 W, 1,500 W, and 1,800 W versions, it delivers high luminous flux suitable for mast-mounted installations and long-throw applications. Power, optics, and orientation are selected based on pitch dimensions, mast height, and requirements regarding illuminance levels, uniformity, glare control, and spill light. Featuring an integrated DALI driver, C5 corrosion resistance, and a rated luminous efficacy of 150 lm/W, ARENA STADIUM is incorporated into comprehensive photometric studies to optimize light distribution, visual comfort, and installed power.

Download

POWER
CCT
Quantity
Stock available :
Stock available :
Last items in stock

gopadma 4 5 0 20

Order properly now and receive it...

between 11/16/26 and 11/17/26  with  Transport Routier

Description

High-power LED floodlight for outdoor sports lighting

ARENA STADIUM

From 600 W to 1,800 W for football pitches, rugby fields, stadiums and large sports facilities

ARENA STADIUM is designed for outdoor installations requiring high luminous output and long-distance projection. Its four power ratings, dedicated optics and adjustable aiming make it possible to create a layout suited to the masts, field dimensions and required lighting level.

600 to 1,800 W 130° × 56° / 110° × 56° optics IP66 · IK08 · C5
600 to 1,800 W

four power ratings

92,336 to 263,000 lm

specified luminous flux depending on version

2 optics

distributions adapted to each power rating

5,700 K

specified colour temperature

138,000 h

specified L80/B10 LED lifetime

A floodlight to be integrated into a complete lighting study

High power is only useful when the light is correctly directed

Lighting a football pitch, rugby field or stadium is not simply a matter of adding watts. Mast height, mast position, setback, floodlight aiming and optical distribution determine field coverage, uniformity and visual comfort.

ARENA STADIUM offers four power ratings to adapt the contribution of each lighting point. A photometric study makes it possible to select the appropriate version, aim the beams and avoid oversizing that would increase energy consumption without guaranteeing better lighting quality.

Outdoor applications

A range designed for large sports areas

Each application requires a specific illuminance level, uniformity, viewing angles and environmental constraints. ARENA STADIUM must therefore be dimensioned according to the actual field and its use.

Outdoor football pitch lit by ARENA STADIUM floodlights
Primary application

Football pitches

The study takes into account the level of play, dimensions, number and height of the masts, horizontal illuminance and, where required, vertical illuminance.

LED lighting project for a rugby field using ARENA STADIUM floodlights
Large playing area

Rugby fields

The width, depth of the field and in-goal areas require precise distribution. High power must remain controlled to maintain uniformity and visual comfort.

Outdoor multi-sport complex lit by high-power LED floodlights
Coordinated configuration

Stadiums and multi-sport complexes

ARENA STADIUM can be considered for facilities comprising several sports areas, stands or a track. Each area must be integrated into the lighting layout.

Outdoor multi-sport facility lit by high-power LED floodlights
Site-specific study

Other large outdoor facilities

The range can be included in studies for other facilities requiring long-distance projection, subject to checking the use, spill light, surrounding properties, wind load and project specifications.

Selection guide

Which ARENA STADIUM power rating should you choose?

A more powerful version is not automatically more suitable. The choice must be made at the scale of the complete installation: masts, number of floodlights, optics, aiming, illuminance level, uniformity and total installed power.

600 W STAAREN600W

For positions or installations requiring controlled individual power

This version uses the 130° × 56° distribution specified in the technical data sheet.

Luminous flux
92,336 lm
Optics
130° × 56°
Dimensions
655 × 266 × 257 mm
Weight
15.3 kg
1,200 W STAAREN1K2W

For increasing luminous output per lighting point on large installations

This version uses the 110° × 56° distribution designed for the high-power versions.

Luminous flux
190,957 lm
Optics
110° × 56°
Dimensions
663 × 462 × 347 mm
Weight
27.6 kg
1,500 W STAAREN1K5W

For projects requiring more luminous output without using the maximum power rating

The specified temperature range for this version is −30 °C to +40 °C.

Luminous flux
221,230 lm
Optics
110° × 56°
Dimensions
663 × 462 × 347 mm
Weight
29.6 kg
1,800 W STAAREN1K8W

For positions requiring the highest individual luminous output in the range

Its weight, dimensions and wind load must be taken into account when designing the supports.

Luminous flux
263,000 lm
Optics
110° × 56°
Dimensions
663 × 685 × 347 mm
Weight
37.9 kg

Optics and visual comfort

Long-distance projection while controlling aiming angles

ARENA STADIUM combines high luminous output with wide, elongated light distributions. Adjustment should not be carried out by eye alone: the aiming of each floodlight must remain consistent with the study in order to cover the field without creating excessive overlit areas or spill light.

130° × 56° Specified distribution for the 600 W version.
110° × 56° Specified distribution for the 1,200 W to 1,800 W versions.
  • Optional anti-glare visor available.
  • Aiming and tilt to be defined individually for each floodlight.
  • Wind load, crossarm strength and maintenance access must be checked.
ARENA STADIUM floodlight fitted with anti-glare visors
Add a view of the product with its visor or a comparative diagram of the light distributions here.

Technical specifications

Four versions for outdoor sports lighting projects

Specification 600 W 1,200 W 1,500 W 1,800 W
ReferenceSTAAREN600WSTAAREN1K2WSTAAREN1K5WSTAAREN1K8W
Power600 W1,200 W1,500 W1,800 W
Colour temperature5,700 K5,700 K5,700 K5,700 K
Luminous flux92,336 lm190,957 lm221,230 lm263,000 lm
Beam angle130° × 56°110° × 56°110° × 56°110° × 56°
Dimensions655 × 266 × 257 mm663 × 462 × 347 mm663 × 462 × 347 mm663 × 685 × 347 mm
Weight15.3 kg27.6 kg29.6 kg37.9 kg
SCX at 15° / 60°0.07 / 0.140.11 / 0.280.11 / 0.220.15 / 0.42
IP66666666
IK08080808
20 kV surge protectionyesyesyesyes
150 lm/W

Specified luminous efficacy in the general presentation.

IP66 · IK08

Protection ratings stated in the technical data sheet.

C5

Specified corrosion category.

Integrated DALI

DALI driver specified in the technical data sheet.

CRI > 70

Specified colour rendering index.

Documented football project

At Champcevinel, 8 ARENA STADIUM 800 W floodlights were studied on 4 × 20 m masts

The Champcevinel football pitch measures 88 × 54 m. The configuration is based on four 20 m masts, positioned in pairs along the longitudinal sidelines, with two ARENA STADIUM 800 W floodlights per mast.

The installed floodlight power is 6.4 kW. The supplied photometric study indicates an average initial illuminance of 140 lux, an average maintained illuminance of 120 lux and a U1h uniformity factor of 0.53.

These values come from the project's photometric study. No post-installation night-time measurement report was included in the supplied documentation, so they must not be presented as on-site measurements.

ARENA STADIUM 800 W floodlights installed on a mast at the Champcevinel football pitch
Two ARENA STADIUM 800 W floodlights per mast in the studied configuration.
Pitch: 88 × 54 m 4 × 20 m masts 8 ARENA STADIUM 800 W 2 floodlights per mast Installed power: 6.4 kW Project objective: E7 level to be confirmed

Photometric study results

A layout designed for local use and training

The study links mast height, the number of floodlights and their aiming to the required lighting level. It also makes it possible to check uniformity and the consistency of the distribution before final adjustment.

140 lux studied initial average illuminance
120 lux studied maintained average illuminance
U1h 0.53 uniformity stated in the study
False-colour view of the photometric study for the Champcevinel football pitch
False-colour view of the photometric study.
3D view of the ARENA STADIUM floodlight layout on the Champcevinel football pitch
3D view of the layout and aiming directions.

STADÉLUM method

Dimension the field before selecting the power rating

STADÉLUM analyses the site and sporting objective before selecting the ARENA STADIUM versions. The project is studied at the scale of the complete installation, rather than floodlight by floodlight.

1. Analyse the site

Dimensions, sport, level of play, masts, crossarms, setback, environment and surrounding properties.

2. Define the objective

Required illuminance, uniformity, competition conditions, training or multi-sport use.

3. Design the layout

Selection of power ratings, optics, positions, aiming directions and control scenarios.

4. Control the risks

Glare, spill light, low-light areas, installed power and wind load.

Photometric study

Check performance before work begins

The photometric study makes it possible to compare several power ratings and aiming configurations, check average illuminance, uniformity and peripheral areas, and then adjust the installed power.

On a large outdoor field, it must also take into account viewing angles, light emitted outside the playing area, the surrounding environment and the requirements of the project specifications or targeted sporting level.

Request a study for my sports field
Photometric study of a football pitch using ARENA STADIUM floodlights
Add an actual, clearly identified layout plan or photometric map here.

Technical resources

Documents for preparing the project

The technical data sheet presents the power ratings, luminous flux values, distributions, dimensions, weights and common characteristics. Photometric files and mounting data can be requested subject to availability.

Frequently asked questions

Correctly dimensioning an ARENA STADIUM project

What types of sports fields is ARENA STADIUM designed for?

ARENA STADIUM is designed for outdoor sports fields requiring high luminous output, particularly football, rugby, stadiums and large multi-sport facilities.

How do I choose between 600 W, 1,200 W, 1,500 W and 1,800 W?

The choice depends on the masts, projection distances, number of floodlights, illuminance level, uniformity and overall installed power. A lighting study makes it possible to compare different configurations.

Which optics are available?

The technical data sheet specifies a 130° × 56° distribution for the 600 W version and a 110° × 56° distribution for the 1,200 W, 1,500 W and 1,800 W versions.

Is the anti-glare visor included?

The visor is presented as an option. Its use must be determined according to aiming, the required visual comfort and its impact on the beam.

Can ARENA STADIUM be controlled via DALI?

The technical data sheet specifies an integrated DALI driver. Control scenarios, dimming levels and control equipment must be defined as part of the electrical project.

Your football pitch, rugby field or sports complex

The ARENA STADIUM power rating must be determined by the project

STADÉLUM analyses the masts, heights, distances, optics, glare, lux targets, uniformity and spill light before proposing a configuration and installed power.

Product Details
Comments (0)
No customer reviews for the moment.