High-power LED floodlight for outdoor sports lighting
From 600 W to 1,800 W for football pitches, rugby fields, stadiums and large sports facilities
ARENA STADIUM is designed for outdoor installations requiring high luminous output and long-distance projection. Its four power ratings, dedicated optics and adjustable aiming make it possible to create a layout suited to the masts, field dimensions and required lighting level.
four power ratings
specified luminous flux depending on version
distributions adapted to each power rating
specified colour temperature
specified L80/B10 LED lifetime
A floodlight to be integrated into a complete lighting study
High power is only useful when the light is correctly directed
Lighting a football pitch, rugby field or stadium is not simply a matter of adding watts. Mast height, mast position, setback, floodlight aiming and optical distribution determine field coverage, uniformity and visual comfort.
ARENA STADIUM offers four power ratings to adapt the contribution of each lighting point. A photometric study makes it possible to select the appropriate version, aim the beams and avoid oversizing that would increase energy consumption without guaranteeing better lighting quality.
Outdoor applications
A range designed for large sports areas
Each application requires a specific illuminance level, uniformity, viewing angles and environmental constraints. ARENA STADIUM must therefore be dimensioned according to the actual field and its use.
Football pitches
The study takes into account the level of play, dimensions, number and height of the masts, horizontal illuminance and, where required, vertical illuminance.
Rugby fields
The width, depth of the field and in-goal areas require precise distribution. High power must remain controlled to maintain uniformity and visual comfort.
Stadiums and multi-sport complexes
ARENA STADIUM can be considered for facilities comprising several sports areas, stands or a track. Each area must be integrated into the lighting layout.
Other large outdoor facilities
The range can be included in studies for other facilities requiring long-distance projection, subject to checking the use, spill light, surrounding properties, wind load and project specifications.
Selection guide
Which ARENA STADIUM power rating should you choose?
A more powerful version is not automatically more suitable. The choice must be made at the scale of the complete installation: masts, number of floodlights, optics, aiming, illuminance level, uniformity and total installed power.
For positions or installations requiring controlled individual power
This version uses the 130° × 56° distribution specified in the technical data sheet.
- Luminous flux
- 92,336 lm
- Optics
- 130° × 56°
- Dimensions
- 655 × 266 × 257 mm
- Weight
- 15.3 kg
For increasing luminous output per lighting point on large installations
This version uses the 110° × 56° distribution designed for the high-power versions.
- Luminous flux
- 190,957 lm
- Optics
- 110° × 56°
- Dimensions
- 663 × 462 × 347 mm
- Weight
- 27.6 kg
For projects requiring more luminous output without using the maximum power rating
The specified temperature range for this version is −30 °C to +40 °C.
- Luminous flux
- 221,230 lm
- Optics
- 110° × 56°
- Dimensions
- 663 × 462 × 347 mm
- Weight
- 29.6 kg
For positions requiring the highest individual luminous output in the range
Its weight, dimensions and wind load must be taken into account when designing the supports.
- Luminous flux
- 263,000 lm
- Optics
- 110° × 56°
- Dimensions
- 663 × 685 × 347 mm
- Weight
- 37.9 kg
Optics and visual comfort
Long-distance projection while controlling aiming angles
ARENA STADIUM combines high luminous output with wide, elongated light distributions. Adjustment should not be carried out by eye alone: the aiming of each floodlight must remain consistent with the study in order to cover the field without creating excessive overlit areas or spill light.
Technical specifications
Four versions for outdoor sports lighting projects
| Specification | 600 W | 1,200 W | 1,500 W | 1,800 W |
|---|---|---|---|---|
| Reference | STAAREN600W | STAAREN1K2W | STAAREN1K5W | STAAREN1K8W |
| Power | 600 W | 1,200 W | 1,500 W | 1,800 W |
| Colour temperature | 5,700 K | 5,700 K | 5,700 K | 5,700 K |
| Luminous flux | 92,336 lm | 190,957 lm | 221,230 lm | 263,000 lm |
| Beam angle | 130° × 56° | 110° × 56° | 110° × 56° | 110° × 56° |
| Dimensions | 655 × 266 × 257 mm | 663 × 462 × 347 mm | 663 × 462 × 347 mm | 663 × 685 × 347 mm |
| Weight | 15.3 kg | 27.6 kg | 29.6 kg | 37.9 kg |
| SCX at 15° / 60° | 0.07 / 0.14 | 0.11 / 0.28 | 0.11 / 0.22 | 0.15 / 0.42 |
| IP | 66 | 66 | 66 | 66 |
| IK | 08 | 08 | 08 | 08 |
| 20 kV surge protection | yes | yes | yes | yes |
Specified luminous efficacy in the general presentation.
Protection ratings stated in the technical data sheet.
Specified corrosion category.
DALI driver specified in the technical data sheet.
Specified colour rendering index.
Documented football project
At Champcevinel, 8 ARENA STADIUM 800 W floodlights were studied on 4 × 20 m masts
The Champcevinel football pitch measures 88 × 54 m. The configuration is based on four 20 m masts, positioned in pairs along the longitudinal sidelines, with two ARENA STADIUM 800 W floodlights per mast.
The installed floodlight power is 6.4 kW. The supplied photometric study indicates an average initial illuminance of 140 lux, an average maintained illuminance of 120 lux and a U1h uniformity factor of 0.53.
These values come from the project's photometric study. No post-installation night-time measurement report was included in the supplied documentation, so they must not be presented as on-site measurements.
Photometric study results
A layout designed for local use and training
The study links mast height, the number of floodlights and their aiming to the required lighting level. It also makes it possible to check uniformity and the consistency of the distribution before final adjustment.
STADÉLUM method
Dimension the field before selecting the power rating
STADÉLUM analyses the site and sporting objective before selecting the ARENA STADIUM versions. The project is studied at the scale of the complete installation, rather than floodlight by floodlight.
1. Analyse the site
Dimensions, sport, level of play, masts, crossarms, setback, environment and surrounding properties.
2. Define the objective
Required illuminance, uniformity, competition conditions, training or multi-sport use.
3. Design the layout
Selection of power ratings, optics, positions, aiming directions and control scenarios.
4. Control the risks
Glare, spill light, low-light areas, installed power and wind load.
Photometric study
Check performance before work begins
The photometric study makes it possible to compare several power ratings and aiming configurations, check average illuminance, uniformity and peripheral areas, and then adjust the installed power.
On a large outdoor field, it must also take into account viewing angles, light emitted outside the playing area, the surrounding environment and the requirements of the project specifications or targeted sporting level.
Request a study for my sports field
Technical resources
Documents for preparing the project
The technical data sheet presents the power ratings, luminous flux values, distributions, dimensions, weights and common characteristics. Photometric files and mounting data can be requested subject to availability.
Frequently asked questions
Correctly dimensioning an ARENA STADIUM project
What types of sports fields is ARENA STADIUM designed for?
ARENA STADIUM is designed for outdoor sports fields requiring high luminous output, particularly football, rugby, stadiums and large multi-sport facilities.
How do I choose between 600 W, 1,200 W, 1,500 W and 1,800 W?
The choice depends on the masts, projection distances, number of floodlights, illuminance level, uniformity and overall installed power. A lighting study makes it possible to compare different configurations.
Which optics are available?
The technical data sheet specifies a 130° × 56° distribution for the 600 W version and a 110° × 56° distribution for the 1,200 W, 1,500 W and 1,800 W versions.
Is the anti-glare visor included?
The visor is presented as an option. Its use must be determined according to aiming, the required visual comfort and its impact on the beam.
Can ARENA STADIUM be controlled via DALI?
The technical data sheet specifies an integrated DALI driver. Control scenarios, dimming levels and control equipment must be defined as part of the electrical project.
Your football pitch, rugby field or sports complex
The ARENA STADIUM power rating must be determined by the project
STADÉLUM analyses the masts, heights, distances, optics, glare, lux targets, uniformity and spill light before proposing a configuration and installed power.
Français
Español
Deutsch
English