Accessories for sports lighting poles
Single- or double-clamp supports for floodlight installation
Available from 0.4 to 2 m, straight crossarms allow one or more floodlights to be arranged at the top of the pole. They can be adapted to the CONICA, SKY, CLIMB or STADIUM ranges, with a clamp diameter defined according to the pole reference. Please note that each floodlight should weigh less than approximately 25 kg.
Product function
Position the floodlights with the spacing defined by the study
The crossarm creates a horizontal mounting area at the top of the pole. Its length must allow the floodlights to be arranged without restricting their orientation, while maintaining the required spacing between units.
The choice should not be based solely on the number of floodlights: their width, weight, wind-exposed surface area, offset and aiming angles must also be taken into account.
Two configurations
Single clamp for compact configurations, double clamp for longer lengths
TR 400 SB and TR 1100 SB
Two versions measuring 0.4 and 1.1 m, with a U 100 section and one clamp. They are suitable for compact configurations when the pole capacity and floodlight arrangement allow it.
TR 1100 DB to TR 2500 DB
Four lengths from 1.1 to 2 m, with a U 140 section and two clamps. These versions are intended for longer configurations or those requiring a connection distributed over two points.
Available references
Lengths, sections, weights and Scx
| Reference | L | Section | Clamps | Weight | Scx |
|---|---|---|---|---|---|
| TR 400 SB | 0.4 m | U 100 | 1 | 4 kg | 0.05 m² |
| TR 1100 SB | 1.1 m | U 100 | 1 | 10 kg | 0.15 m² |
| TR 1100 DB | 1.1 m | U 140 | 2 | 14 kg | 0.21 m² |
| TR 1500 DB | 1.5 m | U 140 | 2 | 21 kg | 0.29 m² |
| TR 2000 DB | 2.0 m | U 140 | 2 | 23 kg | 0.41 m² |
Mechanical verification: the weight and Scx of the crossarm are added to those of the floodlights, mounting plates and other accessories. The complete pole-top assembly must be compared with the pole capacities.
Compatibility
One crossarm family, with clamps adapted to the pole
Each card links to the relevant pole product page. The presence of a link does not replace verification of the clamp diameter, pole top, floodlight weight, Scx and wind conditions.
For low- or medium-height poles, depending on the pole-top diameter and the capacity of the selected reference.
View the CONICA 20000 product pageFor high-mast tapered cylindrical poles, after checking the diameter, clamp position and pole top.
View the SKY / CLIMB product pageFor polygonal poles, with an interface and clamp geometry adapted to the section of the selected reference.
View the SKY / CLIMB product pageFor 12- or 16-sided poles, depending on height, pole-top configuration and permissible loads.
View the STADIUM product pageFloodlight associated with straight crossarms
SMASH: a medium-power floodlight to consider with a straight crossarm
The SMASH sports LED floodlight is available in 300 W and 500 W versions. With stated weights of 6.4 kg and 10.9 kg, both versions remain below the approximately 25 kg per floodlight indication mentioned on this page.
However, this weight criterion alone is not sufficient to validate the installation. The crossarm length, number of floodlights, their spacing, Scx, orientation, fasteners and pole capacity must be checked together.
Technical documentation
Confirm the clamp and configuration before ordering
The crossarm reference must be matched with the appropriate clamp diameter, pole, floodlights and wind conditions for the project.
Frequently asked questions
Choosing a straight crossarm for floodlights
What is the difference between a single and double clamp?
The single clamp uses one connection point. The double clamp distributes the connection over two points and is used on U 140 versions from 1.1 to 2 m.
Are these crossarms compatible with all poles?
They can be adapted to CONICA, SKY, CLIMB and STADIUM poles, but the diameter and geometry of the clamps must be defined according to the exact reference.
How do you choose the length?
The length depends on the number and width of the floodlights, their spacing, the orientations defined by the photometric study and the pole capacities.
Should the weight of the crossarm be added to the floodlights?
Yes. Its weight and Scx are part of the complete pole-top assembly and must be taken into account in the mechanical verification.
Technical selection
Define the length, clamps and floodlights as a complete assembly
Send us the pole reference, number of floodlights, their dimensions and the required orientations. STADÉLUM will help you select the appropriate crossarm and clamp diameter.